Firefighters in protective gear and helmets kneeling in front of a large blaze

K21045 SCP02 Fire Protection Systems for Chemical Storage (Storage of Liquid Fuels) in Buildings

Preventing pool fires in chemical storage facilities is critical for safety. When flammable liquids escape during an incident, they can cause a powerful pool fire. To ensure maximum protection, strict requirements apply to the storage of flammable liquids. Kiwa developed the Specific Certification Program (SCP02) “Extinguishing of Pool Fires (Liquid Fuels)” to test and certify the performance of fire protection systems for chemical storage. This program focuses on systems designed to extinguish indoor liquid pool fires effectively.

Receive a quote tailored to your needs

Part of the K21045 TIC Scheme

SCP02 is part of the K21045 Fire Protection Systems Test, Inspection and Certification (TIC) scheme. It defines the requirements for obtaining a product certificate for extinguishing systems for liquid fuels.

Why choose SCP02 certification?

  • Demonstrates the effectiveness of fire suppression systems in pool fire scenarios
  • Enables manufacturers to design systems for chemical storage safety
  • Provides benchmarking for fire protection system performance
  • Supports continuous improvement and innovation in fire safety solutions

How the Test Works

The test is conducted in a sufficiently airtight room. Doors and windows must be closed; however, a limited “open” area may be present, such as small gaps between walls and ceilings. Any forced ventilation system or device that affects the room’s airtightness must be switched off.

The test must be based on the exact calculation of grams per unit volume, as this determines the value specified by the supplier. No physical obstacles may be present in the room. The minimum performance requirement for this test involves a liquid pool fire of 2 m², using n-heptane as the test fluid. The energy produced by this fire is approximately 6 megawatts.

For full procedures and performance requirements, refer to the Specific Certification Program SCP02.

The test result is included in the annex of the product certificate. Based on this test, approval under the TIC scheme K21045 Fire Protection Systems is possible.

Want to certify your fire protection system?

Contact Kiwa today to learn more about SCP02 testing and certification.

Certified companies

Search for certificates by entering a company name or certificate number in the search bar.

K21045 Fire Protection Systems

The K21045 Fire Protection Systems is the assessment scheme for testing, inspection and certification (TIC) of fixed fire protection systems. This scheme therefore focuses primarily on manufacturers, installers and maintenance companies and offers these parties the opportunity to deliver products and services with verifiably a high degree of quality assurance within the wide range of fixed fire protection systems. But end users also have an interest in a conclusive quality chain. The objective of this TIC scheme K21045 is to improve safety and security through uniform application of the relevant international standards relating to fire protection systems.

Why Kiwa Fire Safety & Security?

Kiwa Fire Safety & Security (Kiwa FSS) is a leading testing, inspection and certification (TIC) company, focusing on products, installations and companies in the field of fire and burglary protection. Kiwa FSS provides services in an expert, flexible, customer-oriented and innovative manner. These services include conducting inspections, certifying (fire) security companies, testing products and providing training from a fully independent, objective and integral position.

Related services

K21045 SCP01 Fire extinguishing generators based on the extinguishing medium nitrogen

The specific certification program ‘SCP01 N2 Generators’ focuses on fire suppression generators that use nitrogen as the extinguishing agent, also referred to as nitrogen generators based on a solid condensed compound. SCP01 is conducted under the TIC scheme ‘K21045 Fire Protection Systems’ and outlines the requirements Kiwa applies when issuing a product certificate for N2 fire suppression generators.

Fire alarm system sprinklers

K21045 SCP03 – The Certification Programme for Fire Safety in Marine Engine Rooms

Fires in marine engine rooms pose a significant risk to crew, vessel, and cargo. To ensure safety at sea, ships must comply with strict fire‑protection regulations. Many vessels are equipped with advanced fire‑suppression systems, but their effectiveness must be demonstrated. To support this need, Kiwa has developed the specific certification programme SCP03 – Extinguishing of Large-Scale Fires, Extinguishing of Large Fuel and Operational Fires in Maritime Applications. This programme verifies the performance of fire‑protection systems designed to tackle major fuel and operational fires in the maritime sector.

K21045 SCP04 Central Equipment for Fire Protection Systems with Solid Compound Generators

Technical developments in fire protection systems are continuously evolving. Increasingly, systems equipped with generators that produce their own extinguishing media are entering the market. These are typically aerosol-based, but nitrogen-based systems are also emerging. To address these innovations, specific quality requirements have been established and formalized in the certification scheme: ‘K21045 - SCP04 Control & Indicating Equipment and Control for Automatic Fire Protection Equipment and Fire Protection Systems Based on Solid Bound Compound (SBC) Generators’.