Fire Safety Inspection / Inspection Fire Safety By Kiwa
Receive a quote tailored to your needs
We apply an integral approach combining fire safety engineering and our extensive theoretical knowledge, whilst keeping the effectiveness of the implemented measures in mind.
Inspections and fire safety checks can be based on various starting points:
Inspection in accordance with the Bouwbesluit (‘Building Code’) (assessment fire safety in structures). An inspection based on the Bouwbesluit includes the various fire safety aspects in a building, such as fire compartmentation, strength of support structure during a fire, smoke spread, emergency lighting, egress route signage and firefighting lifts.
Inspection in accordance with NEN 6059
An inspection in accordance with NEN 6059 (since 2015) applies the method established in the standard using a web tool. This method comprises 328 questions covering all aspects of the Bouwbesluit about fire safety. The standard differentiates between a baseline assessment and a status assessment. The advantage of this standard is that inspection results can be benchmarked against other buildings.
Inspection in accordance with ‘Verscherpt Toezicht’ (‘Strict Supervision’)
National Government projects are regularly conducted under so-called 'strict supervision', where a more specific fire safety assessment is conducted, supplementary to ‘regular supervision’. Basic assumptions are assessed prior to inspection. During the inspection, fire safety provisions are assessed based on both certificates as well as the inspector’s experience and knowledge.
Inspection in accordance with VIVB Inspection Scheme
The inspection scheme of the Vereniging van Inspectie-Instellingen voor Veiligheid en Brandveiligheid (VIVB) (‘Association of Inspection Institutions for Safety and Fire Safety’) is an inspection method in which fire compartmentation and strength of support structure during a fire are the most important aspects. Potentially, these aspects can be assessed in cohesion with a fixed fire extinguishing system (such as a sprinkler system).
Why Kiwa FSS?
Kiwa Fire Safety & Security (Kiwa FSS) is a leading Inspection Institution for Fire Safety and Security, providing services combining expertise, flexibility, customer-focus with an innovative attitude. We conduct inspections and provide training maintaining a fully independent, unbiased and fair position. Kiwa FSS operates in a wide range of facilities, including health care, tunnels, logistical, industrial, (petro) chemical, data centres, airports, storage of hazardous goods and hotels.
Inspection Smoke Control Systems (RCS)
Smoke control systems (RBS) must create a smoke-free egress route for the building’s occupants. Because regulations and unambiguous basic assumptions are largely not available, it is important to work with partners with sufficient knowledge. Kiwa is such an expert partner.

Quick scan Fire Safety in Buildings
Kiwa FSS’s quick scan Fire Safety in Buildings is an independent investigation to determine the current status of fire safety precautions.

K21045 Fire Protection Systems
The K21045 Fire Protection Systems Assessment scheme is a scheme for Testing, Inspecting and Certification (TIC) Fire Protection Systems.

Inspection Fire alarm and Evacuation Alarm Systems
In case of fire, fire alarm and evacuation alarm systems are crucial for the safety of occupants in a building and minimising damage. Kiwa R2B is the expert for inspection and certification of fire alarm systems and evacuation alarm systems, see here for more information!

K23003 Fire Extinguishing Systems based on Dry Aerosol
The K23003 describes the processes with regard to supplying of the basic- and detailed design, installation and the maintenance of fixed fire-extinguishing systems based on condensed dry aerosol for structures and compartments.

Inspection PGS 15 Publicatie reeks Gevaarlijke Stoffen (Publication Series on Hazardous Substances)
Guideline 15 from the Publication Series on Hazardous Substances (PGS) contains guidance for the storage of packaged hazardous goods. Kiwa FSS can assess the fire safety aspects in your storage facility during an inspection PGS 15, including from baseline inspection to PGS 15 certification and follow-up inspection.

Electronic Security Certification in accordance with BRL-K21035
Electronic Security Certification in accordance with BRL-K21035.